Begriffe in "doppelten Anführungszeichen" werden in folgenden Begriffsbestimmungen erläutert: [EU] "All compensations available" (2) means after all feasible measures available to the manufacturer to minimise all systematic positioning errors for the particular machine-tool model are considered. "Allocated by the ITU" (3 5) means the allocation of frequency bands according to the ITU Radio Regulations (Edition 1998) for primary, permitted and secondary services. N.B.: Additional and alternative allocations are not included. "Angular position deviation" (2) means the maximum difference between angular position and the actual, very accurately measured angular position after the workpiece mount of the table has been turned out of its initial position (ref. VDI/VDE 2617, Draft: 'Rotary tables on coordinate measuring machines'). "Asymmetric algorithm" (5) means a cryptographic algorithm using different, mathematically-related keys for encryption and decryption.

Bei der Anwendung der einheitlichen Grundsätze gemäß Anhang VI sind die Schlussfolgerungen des vom Ständigen Ausschuss für die Lebensmittelkette und Tiergesundheit abgeschlossenen Beurteilungsberichts über Kieselgur (SANCO/2617/2008) und insbesondere dessen Anlagen I und II zu berücksichtigen. [EU] For the implementation of the uniform principles of Annex VI, the conclusions of the review report on kieselgur (SANCO/2617/2008) and in particular Appendices I and II thereof, as finalised in the Standing Committee on the Food Chain and Animal Health shall be taken into account.

Bei der Anwendung der einheitlichen Grundsätze gemäß Artikel 29 Absatz 6 der Verordnung (EG) Nr. 1107/2009 sind die Schlussfolgerungen des vom Ständigen Ausschuss für die Lebensmittelkette und Tiergesundheit abgeschlossenen Beurteilungsberichts über Kieselgur (SANCO/2617/2008) und insbesondere dessen Anlagen I und II zu berücksichtigen. [EU] For the implementation of the uniform principles as referred to in Article 29(6) of Regulation (EC) No 1107/2009, the conclusions of the review report on kieselgur (SANCO/2617/2008) and in particular Appendices I and II thereof, as finalised in the Standing Committee on the Food Chain and Animal Health shall be taken into account.

Das Prüfmittel, das bei Bestimmung der "Messunsicherheit" eines Längenmesssystems verwendet wird, soll dem in VDI/VDE 2617 Teil 2, 3 und 4 beschriebenen entsprechen. [EU] The probe used in determining the measurement uncertainty of a dimensional inspection system shall be described in VDI/VDE 2617 parts 2, 3 and 4.

Das Prüfmittel, das bei Bestimmung der "Messunsicherheit" eines Längenmesssystems verwendet wird, soll dem in VDI/VDE 2617 Teile 2, 3 und 4 beschriebenen entsprechen. [EU] The probe used in determining the measurement uncertainty of a dimensional inspection system shall be described in VDI/VDE 2617 parts 2, 3 and 4.

Dazu gehören keine Algorithmen, die nur lineare oder Drehtransformation eines einzelnen Bildes verwenden wie Translation, Merkmalauszug, Bilderfassung oder Falschfarbendarstellung. [EU] "Angular position deviation" (2) means the maximum difference between angular position and the actual, very accurately measured angular position after the workpiece mount of the table has been turned out of its initial position (ref. VDI/VDE 2617, Draft: 'Rotary tables on coordinate measuring machines').

eine eindimensionale Längen-"Messunsicherheit" kleiner (besser)/gleich (1,25 + L/1000) µm, gemessen mit einem Prüfmittel mit einer Genauigkeit kleiner (besser) als 0,2 µm (L ist die Länge in mm) (Ref. VDI/VDE 2617 Teil 1 und Teil 2) [EU] a one-dimensional length "measurement uncertainty" equal to or less (better) than (1,25 + L/1000) μ;m tested with a probe of an "accuracy" of less (better) than 0,2 μ;m (L is the measured length in millimetres) (Ref.: VDI/VDE 2617 Parts 1 and 2)

Erze der Positionen 2601 bis 2617 sind Mineralien, die die metallurgische Industrie zum Gewinnen von Quecksilber, von Metallen der Position 2844 oder von Metallen der Abschnitte XIV oder XV verwendet, auch wenn sie zu nichtmetallurgischen Zwecken bestimmt sind. [EU] For the purposes of headings 2601 to 2617, the term 'ores' means minerals of mineralogical species actually used in the metallurgical industry for the extraction of mercury, of the metals of heading 2844 or of the metals of Section XIV or XV, even if they are intended for non-metallurgical purposes.

Erze der Positionen 2601 bis 2617 sind Mineralien, die die metallurgische Industrie zum Gewinnen von Quecksilber, von Metallen der Position 2844 oder von Metallen des Abschnitts XIV oder XV verwendet, auch wenn sie zu nichtmetallurgischen Zwecken bestimmt sind. [EU] For the purposes of headings 2601 to 2617, the term 'ores' means minerals of mineralogical species actually used in the metallurgical industry for the extraction of mercury, of the metals of heading 2844 or of the metals of Section XIV or XV, even if they are intended for non-metallurgical purposes.

Fernmeldegesetz vom 30. April 1997 (FMG), (AS 1997 2187), zuletzt geändert am 12. Juni 2009 (AS 2010 2617) [EU] Federal Law of 30 April 1997 on telecommunications (LTC); (RO 1997 2187), as last amended on 12 June 2009 (RO 2010 2617)

"Mechanisches Legieren" (1) (mechanical alloying): ein Legierungsverfahren, das sich aus der Bindung, Zerbrechung und Wiederbindung elementarer und Vorlegierungspulver durch mechanischen Aufprall ergibt. [EU] It includes the uncorrected systematic deviations, the uncorrected backlash and the random deviations (ref. ISO 10360-2, or VDI/VDE 2617). "Mechanical Alloying" (1) means an alloying process resulting from the bonding, fracturing and rebonding of elemental and master alloy powders by mechanical impact.

"Messunsicherheit" (2) (measurement uncertainty): die Kenngröße, die angibt, in welchem Bereich um den angegebenen Wert der richtige Wert der Messgröße mit einer statistischen Sicherheit von 95 % (Bezug: VDI/VDE 2617, Blatt 1) oder 100 % (Bezug: ISO 10360-2) liegt. [EU] "Measurement uncertainty" (2) is the characteristic parameter which specifies in what range around the output value the correct value of the measurable variable lies with a confidence level of 95 %.

Sie dürfen jedoch nicht anders aufbereitet sein, als es bei Erzen für die metallurgische Industrie üblich ist. [EU] Headings 2601 to 2617 do not, however, include minerals which have been submitted to processes not normal to the metallurgical industry.

Sie umfasst die nicht korrigierten, systematischen Abweichungen, die nicht korrigierte Umkehrspanne und die zufälligen Abweichungen (Bezug: ISO 10360-2 oder VDI/VDE 2617). [EU] It includes the uncorrected systematic deviations, the uncorrected backlash and the random deviations (ref. ISO 10360-2, or VDI/VDE 2617). "Mechanical Alloying" (1) means an alloying process resulting from the bonding, fracturing and rebonding of elemental and master alloy powders by mechanical impact. Non-metallic particles may be incorporated in the alloy by addition of the appropriate powders. "Melt Extraction" (1) means a process to 'solidify rapidly' and extract a ribbon-like alloy product by the insertion of a short segment of a rotating chilled block into a bath of a molten metal alloy. N.B.:'Solidify rapidly': solidification of molten material at cooling rates exceeding 1,000 K/s. "Melt Spinning" (1) means a process to 'solidify rapidly' a molten metal stream impinging upon a rotating chilled block, forming a flake, ribbon or rod-like product. N.B.:'Solidify rapidly': solidification of molten material at cooling rates exceeding 1,000 K/s.

Sie umfasst die nicht korrigierten, systematischen Abweichungen, die nicht korrigierte Umkehrspanne und die zufälligen Abweichungen (Bezug: ISO 10360-2 oder VDI/VDE 2617). [EU] "Multichip integrated circuit" (3) means two or more "monolithic integrated circuits" bonded to a common "substrate".

Sie umfasst die nicht korrigierten, systematischen Abweichungen, die nicht korrigierte Umkehrspanne und die zufälligen Abweichungen. [EU] It includes the uncorrected systematic deviations, the uncorrected backlash and the random deviations (ref. ISO 10360-2, or VDI/VDE 2617). "Mechanical Alloying" (1) means an alloying process resulting from the bonding, fracturing and rebonding of elemental and master alloy powders by mechanical impact. Non-metallic particles may be incorporated in the alloy by addition of the appropriate powders. "Melt Extraction" (1) means a process to 'solidify rapidly' and extract a ribbon-like alloy product by the insertion of a short segment of a rotating chilled block into a bath of a molten metal alloy. N.B.:'Solidify rapidly': solidification of molten material at cooling rates exceeding 1000 K/s. "Melt Spinning" (1) means a process to 'solidify rapidly' a molten metal stream impinging upon a rotating chilled block, forming a flake, ribbon or rod-like product. N.B.:'Solidify rapidly': solidification of molten material at cooling rates exceeding 1000 K/s.

"Weltraumgeeignet" (3 6) (space qualified): Produkte, die so konstruiert, gefertigt und geprüft wurden, dass sie die besonderen elektrischen, mechanischen oder umgebungsbedingten Anforderungen für die Verwendung beim Start und Einsatz von Satelliten oder Höhen-Flugsystemen, die in Höhen von 100 km und mehr operieren, erfüllen. "Winkelpositionsabweichung" (2) (angular position deviation): die maximale Differenz zwischen der angezeigten Winkelposition und der richtigen Winkelposition, die mit Hilfe eines genauen Messverfahrens nach Drehung der Werkstückaufnahme eines Drehtisches aus einer Anfangsposition ermittelt wird (Bezug: VDI/VDE 2617, Blatt 4/Teil 4 "Drehtische auf Koordinatenmaschinen"). [EU] Meaning

"Winkelpositionsabweichung" (2) (angular position deviation): die maximale Differenz zwischen der angezeigten Winkelposition und der richtigen Winkelposition, die mit Hilfe eines genauen Messverfahrens nach Drehung der Werkstückaufnahme eines Drehtisches aus einer Anfangsposition ermittelt wird (Bezug: VDI/VDE 2617, Blatt 4/Teil 4 Drehtische auf Koordinatenmessmaschinen). "Wissenschaftliche Grundlagenforschung" (ATA NTA) (basic scientific research): experimentelle oder theoretische Arbeiten hauptsächlich zur Erlangung von neuen Erkenntnissen über grundlegende Prinzipien von Phänomenen oder Tatsachen, die nicht in erster Linie auf ein spezifisches praktisches Ziel oder einen spezifischen praktischen Zweck gerichtet sind. [EU] Meaning ABEC

"Winkelpositionsabweichung" (2) (angular position deviation): die maximale Differenz zwischen der angezeigten Winkelposition und der richtigen Winkelposition, die mit Hilfe eines genauen Messverfahrens nach Drehung der Werkstückaufnahme eines Drehtisches aus einer Anfangsposition ermittelt wird (Bezug: VDI/VDE 2617, Blatt 4/Teil 4 Drehtische auf Koordinatenmessmaschinen). [EU] The setting of function controls including entry of parameters.

The example sentences [G] were kindly provided by the Goethe Institute.